Lot 12 · Inspection log
Existing shared inspection-log concept · Fictional saved records
Sample records only. In the product, the 20-step list is created per home; company-wide template editing is not yet released.
GUIDED SCENARIO · INSPECTION LOG
Failed inspection, corrections and reinspection
BEFORE · FICTIONAL RECORDS
Strapping inspection scheduled
Strapping inspection · Mon Nov 9 (moved from Nov 5 after the sheathing delay). Dry-In is planned for Nov 10.
- Strapping
- Wall / Roof Dry-In
- Cedar Grove · Lot 12
STEP 1 OF 6 · SUPERINTENDENT · ALEX MORGAN
GenStruc workflow · sample records · not AIInspection failed
Failed · Nov 9 · county inspector (fictional).
Correction notes
1. Missing hurricane strap at garage header.
2. Two straps short-nailed at rear wall.
A pass or fail needs the date the inspection actually happened. Nothing passes automatically.
STEP 2 OF 6 · SUPERINTENDENT · ALEX MORGAN
GenStruc workflow · sample records · not AIDry-In blocked until reinspection
Wall / Roof Dry-In · Blocked Nov 9 · reason: strapping reinspection required. The roofing crew is told before they mobilize.
STEP 3 OF 6 · AI
Homebuilding AI · in development, not yet verified · sample outputWhat this means for Lot 12
Summary
Dry-In cannot start until 2 strapping corrections are fixed and the reinspection passes. If the reinspection happens Nov 11, Dry-In starts 1 workday later than planned.
STEP 4 OF 6 · PINE RIDGE FRAMING · REVIEWED BY ALEX MORGAN
GenStruc workflow · sample records · not AICorrections completed
| Correction | Done | Checked by |
|---|---|---|
| Hurricane strap at garage header | Nov 10 | Alex Morgan |
| Re-nail rear wall straps | Nov 10 | Alex Morgan |
STEP 5 OF 6 · SUPERINTENDENT · ALEX MORGAN
GenStruc workflow · sample records · not AIReinspection scheduled
Reinspection #2 · Wed Nov 11, morning.
STEP 6 OF 6 · SUPERINTENDENT · ALEX MORGAN
GenStruc workflow · sample records · not AIReinspection passed
Passed · Nov 11 · attempt 2. Dry-In resumes Nov 11.
The failure, both corrections and the reinspection stay on the home’s record.
Result
A failed inspection becomes a short, tracked fix list, and no crew is sent before the home is ready.
Related:Home schedule
Scripted sample: prewritten from this demo’s fictional records. No AI runs on these pages, and nothing is saved or sent. Labels: GenStruc workflow · sample records · not AI / Homebuilding AI · in development, not yet verified · sample output.
Inspections
Fictional records| Inspection | Scheduled | Result | Correction | Reviewer |
|---|---|---|---|---|
| Footer | Oct 19 | Passed · sample | None | Inspector · fictional |
| Monoslab | Oct 26 | Passed · sample | None | Inspector · fictional |
| Strapping | Nov 9 (moved from Nov 5) | Scheduled | Not inspected | County inspector · fictional |
SELECTED CONTEXT
Strapping
Scheduled: Nov 9. Result: not entered.
Authority / inspector confirmation remains a human task.
No automatic pass, correction clearance or certificate of occupancy.
View the unsaved templateExact 20-item template · unsaved preview
- FooterNot inspected
- StemwallNot inspected
- Plumbing UndergroundNot inspected
- Electric Underground / BondingNot inspected
- MonoslabNot inspected
- Block / LintelNot inspected
- Wall / Roof SheathingNot inspected
- StrappingNot inspected
- Wall / Roof Dry-InNot inspected
- Plumbing Rough / TubsetNot inspected
- Mechanical RoughNot inspected
- Electrical RoughNot inspected
- Window / DoorNot inspected
- FrameNot inspected
- InsulationNot inspected
- DrywallNot inspected
- Mechanical FinalNot inspected
- Plumbing FinalNot inspected
- Pre-Power / Electrical FinalNot inspected
- Building FinalNot inspected
Not editable or saved in this static demo. No inspection migration activated.